sterowniki silników krokowych sterowniki silników krokowych sterowniki silników krokowych sterowniki silników krokowych

CF211.PUR – przewód danych

4.7777777777778 1 1 1 1 1 1 1 1 1 1 Ocena 4.78 (9 głosów)
CF211.PUR – przewód danych

1. Pressure extruded
2. Highly bending-resistant braided copper shield
3. Every 2 cores stranded with short pitch lengths
4. Fine-wire special conductor

  • for high load requirements
  • PUR outer jacket
  • shielded, twisted-pair
  • Notch-resistant
  • PVC and halogen-free
  • Flame retardant
  • Hydrolysis and microbe-resistant

Classification of the Chainflex® cable:
Class 5.5.3.1
Stressing capacity:
5: Cables for continuous movement in e-chains®, high stressing, radii from 6.8 x d, speed up to 10 m/s
Travel distance:
5: Travel up to 100 m
Oil resistance:
3: Oil resistant (in accordance with DIN EN 50363-10-2)

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.

Dynamic information

Bend radius e-chain® min. 7,5 x d
flexible min. 6 x d
fixed min. 4 x d
Temperature e-chain® -25°C to +80 °C
flexible -40°C to +80°C (based on EN 60811-504)
fixed -50°C to +80°C (based on DIN EN 50305)
v max. Unsupported 5 m/s
gliding 3 m/s
a. max. 50 m/s²
Length of travel Unsupported travel distances and up to 100 m for gliding applications, Class 5

Cable structure

Conductor Very finely stranded special cores of particularly high-flex design made of bare copper wires.
core insulation Mechanically high-quality TPE mixture.
Core structure 2 cores each stranded in pairs with short strand pitch lengths,
core pairs also stranded with short strand pitch lengths.
Core identification Colour code in accordance with DIN 47100.
Intermediate layer Foil taping over the external layer
Overall shield Extremely bend-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical.
Outer jacket PUR mixture adapted to suit the requirements in e-chains®.
Colour: Silver grey (similar to RAL 7001)

Electrical information

Nominal voltage 300/300 V (following DIN VDE 0245)
Testing voltage 1500 V

Properties and approvals

UV resistance Medium
Oil resistance Oil-resistant (following DIN EN 50363-10-2), Class 3
Offshore MUD-resistant following NEK 606 - status 2009
Flame retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1
Halogen-free Following EN 60754
Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992)
UL/CSA Style 10493 and 20233, 300 V, 80 °C
DNV-GL Certified according to GL type testing – Certificate no.: 13 656-14 HH
NFPA Following NFPA 79-2012 chapter 12.9
EAC Certified according to no. TC RU C-DE. ME77.B.01254
CTP Certified according to No. C-DE. PB49.B.00416
CEI Following CEI 20-35
Lead free Following 2011/65/EC (RoHS-II)
Clean room According to ISO Class 1, outer jacket material complies with CF77.UL.05.12.D,
tested by IPA according to standard 14644-1.
CE Following 2014/35/EU
 
Guaranteed service life for this series according to the guarantee conditions
Double strokes*         5 million 7,5 million 10 million
Temperature v max. [m/s] a. max. Length of travel R min. R min. R min.
from/to [°C] unsupported gliding m/s² [m] [factor x d] [factor x d] [factor x d]
-20 / +10 5 3 50 ≤ 100 10 11 12
+10 / +70 7,5 8,5 9,5
+70 / +80 10 11 12

* Higher number of double strokes possible.

 Typical application areas

  • for high load requirements
  • almost unlimited resistance to oil
  • Indoor and outdoor applications with average sun radiation
  • Unsupported travel distances and up to 100 m for gliding applications
  • Machining centres / machine tools, storage and retrieval systems, packaging industry, quick handling, refrigerating areas
alutec2.pngbeta.pngbosch.pngcrc.pngfanar.pngfatek.pngfenes.pngflt2.pnghiwin.pngigus.pngirwin.pngklingspor.pngknipex.pngleadshine.pngloctite.pnglwadshine.pngmeanweell.pngnsk.pngsiemens.pngstanley2.pngstomil.pngteknomotor2.pngyato.pngyg-1.png